Microprocessor Panel:
B. Clamp Unit
|
|
Unit
|
IMS-50
|
IMS-85
|
IMS-85-S
|
IMS-130
|
Clamp Force
|
Tonnes
|
50
|
85
|
85
|
130
|
Clamp Opening Force
|
Tonnes
|
5
|
7
|
7
|
8
|
Close Daylight
|
mm
|
150
|
160
|
435
|
190
|
Open Daylight
|
mm
|
600
|
680
|
1020
|
840
|
Clamp Stroke
|
mm
|
450
|
520
|
620
|
650
|
Size of Moving Platon (H x V)
|
mm
|
500x500
|
625x625
|
625x625
|
650x650
|
Distance Between Tiebar (H x V)
|
mm
|
350x350
|
425x425
|
425x425
|
450x450
|
Fast Closing Speed
|
m/min
|
25
|
27
|
27
|
25
|
Centrat Ejector Hole
|
mm
|
100
|
100
|
100
|
100
|
Locating Ring Step. Dia.
|
mm
|
160
|
160
|
160
|
160
|
Hyd. Ejector Force
|
Tonnes
|
1.8
|
2.75
|
2.75
|
2.9
|
Hyd. Ejector Stroke
|
mm
|
100
|
100
|
100
|
100
|
C. Electrical
|
|
Unit
|
IMS-50
|
IMS-85
|
IMS-85-S
|
IMS-130
|
Pump Drive
|
KW
|
11
|
15
|
15
|
22
|
Heater
|
KW
|
5.6
|
8.6
|
8.6
|
12.1
|
Total Connected Load
|
KW
|
16.6
|
23.6
|
23.6
|
34.1
|
App. Weight
|
MT
|
4.0
|
5.0
|
5.5
|
6.5
|
Hyd. Oil requirement
|
Ltr.
|
220
|
250
|
270
|
320
|
Manufacturing range from 50T to 800 T Specifications for IMS - 150, IMS - 400, IMS - 450, IMS - 515, IMS - 600, IMS - 800 available on request.
Optional Features:
- Hydraulic multiple stroke ejector
- Core/cavity air ejection
- Injection boost system
- Flow moulding (instrusion moulding)
- Secondary locking pressure for power saving
- Magnetic grill for hopper
- Microprocessor based control system
- Photocell circuit
- Zero Injection pressure circuit.
- P-Q Block Hyd system for energy saving
- Variable flow & pressure control axial piston pump for highly energy saving working.
- SSR controlled heater circuit for energy saving and long heater life.
|